Status Bits
There are five status bits which the Line Pack driver sets under certain conditions. Most of these bit positions are configured on the Calculations page.
| Status Bit | Description |
|---|---|
|
Calc error (configurable) |
The error bit can be set on any of the points that the Line Pack driver outputs to on a pack segment. It will be set under any of the following conditions:
|
|
Used in line pack calc (configurable) |
Set on any points used as an input to the Line Pack calculation. For example, if a user specifies the tag “SAMPLE.UIS::POINT1” for the Upstream Pressure input in a rule which is used, then the bit will be set on the point SAMPLE.UIS::POINT1. |
|
Default used (configurable) |
Set on a pack segment if one of its default or base inputs were used for the calculation. |
|
Set by line pack (configurable) |
Set on any value that Line Pack sets. This indicates that the value (and timestamp) was set by the Line Pack driver, for whatever reason. |
|
Unreliable (CygNet Unreliable bit) |
This bit can be set on any of the points that the Line Pack driver outputs to on a pack segment. It will be set under any of the following conditions:
|